Tektronix Thermometer 070-9472-02 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Mesure, test et contrôle Tektronix Thermometer 070-9472-02. Tektronix Thermometer 070-9472-02 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - 070-9472-02

Instruction ManualP5205High Voltage Differential Probe070-9472-02www.tektronix.com

Page 2

General Safety SummaryviP5205 Instructi on ManualDo Not Operate With Suspected Failures. If you suspect there is damageto this product, ha ve it i nsp

Page 3 - WARRANTY

P5205 Instructi on ManualviiService Safety Su mmaryOnly qualified personnel should perform service procedures. Readthis Se rvice Safety Summary and th

Page 4

Service Safety SummaryviiiP5205 Instructi on ManualContacting TektronixPhone 1-800-833-9200*Address Tektronix, Inc.14200 SW Karl Braun DriveP.O. Box 5

Page 5 - Table of Contents

P5205 Instructi on Manual1Getting StartedThis section describes the High Voltage Differential Probe and givesinstructions on how to install and functi

Page 6

Getting Started2P5205 Instructi on ManualONFigure 1: High Voltage Differential Probe

Page 7 - List of Figures

Getting StartedP5205 Instructi on Manual3The P5205 has several features and accessories that make probingand measurement a simpler task. Take a moment

Page 8 - List of Tables

Getting Started4P5205 Instructi on ManualInput Leads. The input leads of the differential probeconnect to the crocodile clips and plunger clamps thatc

Page 9 - General Safety Summary

Getting StartedP5205 Instructi on Manual5Zero Adjust. T he zero adjust allows you t o set t he probeoutput to the zero reference point prior to making

Page 10 - Safety Terms and Symbols

Getting Started6P5205 Instructi on ManualInstallationInstall the P5205 probe as follows:1. Connect the output of the probe to the TEKPROBE input of th

Page 11 - Service Safety Su mmary

Getting StartedP5205 Instructi on Manual7Functional CheckTo make a simple functional check of the P5205 probe, select asource that supplies AC line vo

Page 12 - Contacting Tektronix

Copyright © Tektronix, Inc. All rights reserved.Tektronix products are covered by U.S. and foreign patents, issued andpending. Information in this pub

Page 13 - Getting Started

Getting Started8P5205 Instructi on Manual

Page 14 - P5205 Instructi on Manual

P5205 Instructi on Manual9Operating BasicsTo help you use the High Voltage Differential Probe safe ly andeffectively, this section provides important

Page 15

Operating Basics10P5205 Instructi on ManualMinimizing Risk of RF Burn (probe leads)WARNING. To avoid personal injury, do not handle the probe leadswhe

Page 16

Operating BasicsP5205 Instructi on Manual11Voltage(RMS)1000 V100 VDC or 0 10 M 100 M1MFrequency (Hz)5M 50M500 V50 V100 k 500 kCategory II maximumvolta

Page 17

Operating Basics12P5205 Instructi on ManualBoth ranges are rated for t he m aximum input limits, but you canobtain a useful measurement only if the vo

Page 18 - Installation

Operating BasicsP5205 Instructi on Manual13Figure 3: Twisting the input leadsExtension LeadsThe extension leads allow you to reach widely spaced conne

Page 19 - Functional Check

Operating Basics14P5205 Instructi on ManualWith extension leadsWithout extension leads50 ns/div 50 ns/div250 mv/div250 mv/divFigure 4: HF Transient re

Page 20

P5205 Instructi on Manual15Specificatio nsThe specifications in Tables 2 through 6 apply to a P5205 probeinstalled on a Tektronix TDS 460A oscilloscop

Page 21 - Operating Basics

Specifications16P5205 Instructi on ManualTable 2: Warranted Electrical Characteristics (Cont.)Maximum Operating Input Voltage 500X differential: ± 1.3

Page 22

SpecificationsP5205 Instructi on Manual17Table 3: Certifications and Compliances (Cont.)Installation CategoryDescriptionsTerminals on this product may

Page 23

WARRANTYTektronix warrants that the products that it manufactures and sells will be free from defectsin materials and workmanship for a period of one

Page 24

Specifications18P5205 Instructi on ManualTable 4: Typical Electrical Characteristics (Cont.)Overdrive Recovery < 50 ns to 10% of final value after

Page 25

SpecificationsP5205 Instructi on Manual19Table 5: Typical Mechanical Characteristics (Cont.)Unit Weight (probe only) 11 oz (315 g)Shipping Weight (wit

Page 26 - 250 mv/div

Specifications20P5205 Instructi on ManualTable 6: Nominal Electrical Characteristics (Cont.)Gain Switchable: 1/50 (“50X”) and 1/500 (“500X”)Audible Ov

Page 27 - Specificatio ns

P5205 Instructi on Manual21MaintenanceRefer to this section for information about maintaini ng and servi cingthe High Voltage Differential Probe.For t

Page 28

Maintena nce22P5205 Instructi on ManualTo remove a TEKPROBE interfac e pi n, fi rmly grasp the pointe d tipwith pliers and pull the pin out of the con

Page 29 - Typical Characteristics

Maintena nceP5205 Instructi on Manual23Removing and Replacing the TEKPROBE Interface CollarTo remove the TEKPROBE interface collar, firmly grasp theco

Page 30

Maintena nce24P5205 Instructi on ManualRemoving the Compensation Box CoversTo open the compensation box, follow these steps:1. Press the optional rele

Page 31 - Nominal Characteristics

Maintena nceP5205 Instructi on Manual25TabFigure 10: Replacing the compensation box coverPackaging For Return ShipmentIf possible, use the original pa

Page 32 - Specifications

Maintena nce26P5205 Instructi on Manual

Page 33 - Maintenance

The following servicing instructions are for use only byqualified personnel. To avoid injury, do not perform anyservicing other than that st ated in t

Page 36

P5205 Instructi on Manual27Performan c e Verif icationThe following procedure verifies the warranted electrical characteris-tics of the High Voltage D

Page 37 - Packaging For Return Shipment

Performance Verificati o n28P5205 Instructi on ManualConstruction of Modified BNC AdapterConstruct the modifie d BNC Adapter from a BNC-male-to-dualbi

Page 38 - Maintena nce

Performance VerificationP5205 Instructi on Manual29VisePliersModified BNC adapterPlastic cover removedFigure 12: Removing plastic covers from bi nding

Page 39

Performance Verificati o n30P5205 Instructi on ManualNOTE. These procedures assume that you are using an oscilloscopethat automatically displays the c

Page 40

Performance VerificationP5205 Instructi on Manual3110. Attach the differential probe input l eads (without attachmentaccessories) by sliding the banan

Page 41 - Performan c e Verif ication

Performance Verificati o n32P5205 Instructi on Manual15. Set the calibration generator for 10 V output. Set the attenuationbutton on the probe to 50X

Page 42 - -0035-00 (see

Performance VerificationP5205 Instructi on Manual337. Set the generator to 100 MHz, and set the oscilloscope to5 ns/division. Check for ≥ 2.1 V amplit

Page 43 - Plastic cover removed

Performance Verificati o n34P5205 Instructi on ManualWARNING. To reduce the risk of electric shock, ensure the gene ratoroutput is disabled before mod

Page 44 - Differential Gain Accuracy

P5205 Instructi on Manual35Replaceable PartsThis section contains a list of the replaceable m odules for the P5205probe. Use this list to identify and

Page 45 - Banana plug of probe

P5205 Instructi on ManualiTable of ContentsGeneral Safety Summary v...Service Safety Summary vii...

Page 46 - Bandwidth

Replaceable Parts36P5205 Instructi on ManualTable 8: Parts List Column DescriptionsColumn Column Name Description1 Figure & Index Number Items in

Page 47

Replaceable PartsP5205 Instructi on Manual37123456Figure 14: P5205 Probe and replaceable accessories

Page 48

Replaceable Parts38 P5205 Instructi on ManualP5205 and Replaceable AccessoriesFig. &IndexNumberTektronixPart NumberSerial No.EffectiveSerial No.Di

Page 49 - Replaceable Parts

Replaceable Parts39P5205 Instructi on Manual123NOTE: Parts illustratedwith dashed lines are notreplaceable45Figure 15: Replaceable parts - compensatio

Page 50

Replaceable Parts40 P5205 Instructi on Manual1Figure 16: P5205 optional accessoriesOptional AccessoriesFig. &IndexNumberTektronixPart NumberSerial

Page 51

Replaceable Parts41P5205 Instructi on ManualManufacturers Cross IndexMfr .CodeManufacturer Address City, State, Zip Code18359 PYLON CO. INC. 51 NEWCOM

Page 52 - 38 P5205 Instructi on Manual

Replaceable Parts42 P5205 Instructi on Manual

Page 53

Table of C ontentsiiP5205 Instructi on ManualBandwidth 32...DC CMRR 33...R

Page 54 - Optional Accessories

Table of C ontentsP5205 Instructi on ManualiiiList of FiguresFigure 1: P5205 High-Volt age Differential Probe 2...Figure 2: Safety limits (vol

Page 55 - Manufacturers Cross Index

Table of C ontentsivP5205 Instructi on ManualList of TablesTable 1: Functional Che ck 8...Table 2: Warranted Electrical Chara

Page 56 - 42 P5205 Instructi on Manual

P5205 Instructi on ManualvGeneral Safety SummaryReview the following safety precautions to avoid injury and preventdamage to this product or any produ

Commentaires sur ces manuels