Tektronix TDS544A Manuel d'utilisateur Page 67

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 114
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 66
Performance Tests
TDS 520A, 524A, 540A, & 544A Performance Verification
d.
Modify the initialized front-panel control settings:
Set the horizontal SCALE to 200 s.
Press SHIFT; then ACQUIRE MENU.
Press the main-menu button Mode. Then press the side-menu
button Hi Res.
2.
Confirm Main and Delayed Trigger outputs are within limits for logic
levels:
a.
Display the test signal:
Press WAVEFORM OFF to turn off CH 1; then press CH 2 to
display that channel. Set the vertical SCALE to 1 V.
Press TRIGGER MENU.
Press the main-menu button Source; then press the side-menu
button CH 3. Press SET LEVEL TO 50%.
Use the vertical POSITION knob to center the display on screen.
b.
Measure logic levels:
Press MEASURE; then press the main-menu button Select
Measrmnt for
Ch2
.
Repeatedly press the side-menu button –more– until High and
Low appear in the side menu (their icons are shown at the left).
Press both side-menu buttons High and Low. See Figure 1-22.
First, turn on the
measurements
high and low.
Second, read the
measurement
results here.
Figure 1-22: Measurement of Main Trigger Out Limits
Vue de la page 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 113 114

Commentaires sur ces manuels

Pas de commentaire