Commands Listed in Alphabetical Order
POWer:SWLoss
:CONDuction:POWER:MAX? (Query Only)
Returns the maximum conduction power for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SWLoss:CONDuction:P OWER:MAX?
Examples
POWER:SWLOSS:CONDUCTION:P OWER:MAX? might return
:POWER:SWLOSS:CONDUCTION: POWER:MAX 1 indicating that the
maximum conduction power switching loss calculation is set to 1 W.
POWer:SWLoss:CONDuction:POWER:MEAN? (Query Only)
Returns the mean conduction power for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SWLoss:CONDuction:P OWER:MEAN?
Examples
POWER:SWLOSS:CONDUCTION:P OWER:MEAN? might return
:POWER:SWLOSS:CONDUCTION: POWER:MEAN 1 indicating that the
mean conduction power switching loss calculation is set to 1 W.
POWer:SWLoss:CONDuction:POWER:MIN? (Query Only)
Returns the minimum conduction power for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SWLoss:CONDuction:P OWER:MIN?
2-300 MSO4000 and DPO4000 Series Programmer Manual