Commands Listed in Alphabetical Order
Arguments
<QString> is a q
uoted string that is the low b inary data string to be used for
FLEXRAY trigger condition if trigger condition is ID or IDANDDATA.
Examples
SEARCH:SEARCH1:TRIGGER:A: BUS:B1:FLEXRAY:DATA:VALUE
“11001010”
sets the binary data s tring to 11001010.
SEARCH:SEARCH1:TRIGGER:A: BUS:B1:FLEXRAY:DATA:VALUE? might
return
SEARCH:SEARCH1:TRIGGER:A:BUS :B1:FLEXRAY:DATA:VALUE
"XXXXXXXX"
indicates the binary data string is don’t c ares.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE
Sets or returns the end of frame type used for FLEXRAY trigger.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger: A:BUS:B<x>:FLEXray:EOFTYPE
{STATic|DYNAMic|ANY}
SEARCH:SEARCH<x>:TRIGger: A:BUS:B<x>:FLEXray:EOFTYPE?
Arguments
STATic sets the FLEXRAY end of frame type to STATIC.
DYNAMic sets the FLEXRAY end of frame type to DYNAMIC.
ANY sets the FLEXRAY end of frame type to ANY type.
Examples
SEARCH:SEARCH1:TRIGGER:A: BUS:B1:FLEXRAY:EOFTYPE AN Y sets the
FLEXRAY end of frame type to any type.
SEARCH:SEARCH1:TRIGGER:A: BUS:B1:FLEXRAY:EOFTYPE? might return
SEARCH:SEARCH1:TRIGGER:A: BUS:B1:FLEXRAY:EOFTYPE ST ATIC
indicating the FLEXRAY end of frame type is static.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE
Sets or returns the error type be used for FLEXRAY trigger.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger: A:BUS:B<x>:FLEXray:ERRTYPE
{CRCHeader|CRCTrailer|SYN CFrame|STARTupnosync|NULLFRStatic|
NULLFRDynamic}
SEARCH:SEARCH<x>:TRIGger: A:BUS:B<x>:FLEXray:ERRTYPE?