Tektronix DPO4000 Manuel d'utilisateur Page 418

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 585
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 417
Commands Listed in Alphabetical Order
SYNCFrame sets
the FLEXRAY e rror type for a trigger to SYNCFrame.
STARTupnosync sets the FLEXRAY error type for a trigger to STARTupnosync.
NULLFRStatic sets the FLEXRAY error t ype for a trigger to NULLFRStatic.
NULLFRDynamic sets the FLEXRAY error type for a trigger to NULLFRDynamic.
Examples
TRIGGER:A:BUS:B1:FLEXRAY: ERRTYPE SYNCFRAME sets the FLEXRAY
trigger type is SYNCFRAME.
TRIGGER:A:BUS:B1:FLEXRAY: ERRTYPE? might return
TRIGGER:A:BUS:B1:FLEXRAY: ERRTYPE CRCHEADER indicating the
FLEXRAY trigger type is C RCHeader.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue
Sets or returns the binary data string to be used for FLEXRAY frame ID high
value.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXra y:FRAMEID:HIVALue <QStrin g>
TRIGger:A:BUS:B<x>:FLEXra y:FRAMEID:HIVALue?
Arguments
<QString> is a quoted string that is the binary frame id high value.
Examples
TRIGGER:A:BUS:B1:FLEXRAY: FRAMEID:HIVALUE “11001100101 ” sets the
frame id high value to 11001100101.
TRIGGER:A:BUS:B1:FLEXRAY: FRAMEID:HIVALUE? might return
TRIGGER:A:BUS:B1:FLEXRAY: FRAMEID:HIVALUE "XXXXXXXXXXX "
indicating the frame id high value is don’t care.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALier
Sets or returns the FLEXRAY frame ID qualier.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXra y:FRAMEID:QUALifier
{LESSThan|MOREThan|EQUal| UNEQual|LESSEQual|MOREEQual|
INrange|OUTrange}
2-408 MSO4000 and DPO4000 Series Programmer Manual
Vue de la page 417
1 2 ... 413 414 415 416 417 418 419 420 421 422 423 ... 584 585

Commentaires sur ces manuels

Pas de commentaire